Specifications (PDF)
EX612: 400A Dual Input AC Clamp Meter + NCV
AC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector
Features:
- True RMS measurements for accurate AC Voltage and Current measurements
- Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2)
- Built-in non-contact Voltage detector with LED alert
- DC µA multimeter function for HVAC flame rod Current measurements
- Data Hold plus fast Peak Hold of current surges during motor startup
- 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
- Measures motor capacitors to 40,000µF
- 1.25″ (32mm) jaw opening for conductors up to 500MCM
- Rugged double molded housing
- Auto power off with audible alert and disable function
- Autoranging with manual override
- Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes (-4 to 482°F/-20 to 250°C), and case
EX613: 400A Dual Input AC/DC Clamp Meter + NCV
AC/DC Clamp-on meter with built-in dual Thermocouple inputs and Non-contact Voltage Detector
Features:
- True RMS measurements for accurate AC Voltage and Current measurements
- Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2)
- Built-in non-contact Voltage detector with LED alert
- DC µA multimeter function for HVAC flame rod Current measurements
- Data Hold plus fast Peak Hold of current surges during motor startup
- 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
- Measures motor capacitors to 40,000µF
- 1.25″ (32mm) jaw opening for conductors up to 500MCM
- Rugged double molded housing
- Auto power off with audible alert and disable function
- Autoranging with manual override
- Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes (-4 to 482°F/-20 to 250°C), and case
EX622: 400A Dual Input AC Clamp Meter + NCV + IR Thermometer
AC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer
Features:
- True RMS measurements for accurate AC Voltage and Current measurements
- Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2)
- Built-in non-contact IR Thermometer with laser pointer for locating hot spots (up to 518°F/270°C)
- Built-in non-contact Voltage detector with LED alert
- DC µA multimeter function for HVAC flame rod Current measurements
- Data Hold plus fast Peak Hold of current surges during motor startup
- 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
- Measures motor capacitors to 40,000µF
- 1.25″ (32mm) jaw opening for conductors up to 500MCM
- Rugged double molded housing
- Auto power off with audible alert and disable function
- Autoranging with manual override
- 8 to 1 distance to target ratio
- Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes (-4 to 482°F/-20 to 250°C), and case
EX623: 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer
AC/DC Clamp-on meter with built-in dual Thermocouple inputs, NCV Detector and InfraRed Thermometer
Features:
- True RMS measurements for accurate AC Voltage and Current measurements
- Dual type K thermocouple input with Differential Temperature function (T1, T2, T1-T2)
- Built-in non-contact IR Thermometer with laser pointer for locating hot spots (up to 518°F/270°C)
- Built-in non-contact Voltage detector with LED alert
- DC µA multimeter function for HVAC flame rod Current measurements
- Data Hold plus fast Peak Hold of current surges during motor startup
- 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
- Measures motor capacitors to 40,000µF
- 1.25″ (32mm) jaw opening for conductors up to 500MCM
- Rugged double molded housing
- Auto power off with audible alert and disable function
- Autoranging with manual override
- 8 to 1 distance to target ratio
- Complete with CAT III-600V, double molded test leads, 9V battery, two Type K bead wire probes (-4 to 482°F/-20 to 250°C), and case
Be the first to review “400A Dual Input Clamp Meter”