What’s Included:
TL-88-1 test leads, 6AM6X battery and CA-05A carrying case
Specifications:
Functional Specifications
Current
Range: 40A, 400A, 1000A AC/DC
Resolution: 0.01A, 0.1A, 1A AC/DC
Accuracy: AC: ±(1.9% rdg. +5 dgt.); DC: ±(2.5% rdg. +10 dgt.)
Voltage
Range: AC: 400V, 750V; DC: 400V, 1000V
Resolution: 0.1, 1V AC/DC
Accuracy: AC: ±(1.5% rdg. +5 dgt.); DC: ±(1% rdg. +2 dgt.)
Resistance
Range: 400Ω, 4000Ω
Resolution: 0.1Ω, 1Ω
Accuracy: ±(1% rdg. +3 dgt.)
Frequency
Range: A & V: 4kHz, 10kHz
Resolution: 1Hz, 10Hz
Accuracy: A-Hz: ±(0.1% rdg. +1 dgt.) (20Hz-10kHz); V-Hz: ±(0.1% rdg. +1 dgt.) (10Hz-10kHz)
Continuity Range: < 100Ω
Test Current Range: 1.7 mA max.
General Specifications
Power Supply: Single 9V battery
Battery Life: Approx. 100 hours
Jaw Opening: 40mm
Dimensions: 242 x 66 x 36mm (9.5 x 2.6 x 1.4″)
Weight: 400g (10 oz)
Be the first to review “True RMS AC/DC Clamp Meter”