• True amperometric test method • Measures free or total chlorine residuals • Applications include fresh water, wastewater, and food processing • Simple to calibrate and operate • Uses inexpensive, non-toxic, food-grade vinegar for pH buffering • Continuous, isolated, 4-20 milliamp output signal, suitable for control or monitoring applications • Built-in high and low alarm relays • Field-adjustable range • High range capabilities to 100 ppm without dilution |
The Foxcroft FX-1000p Chlorine Residual Analyzer utilizes the most accurate test method to determine chlorine residual levels in process waters, similar to that used in lab environment titrator test methods. This makes it an excellent choice for chlorine control or monitoring applications. Residual readings are instantaneous and do not rely on “sample and hold” methods. This minimizes any delay in readings for control applications. The continuous 4-20 milliamp output signal can be used to drive chlorine residual control systems and/or chart recorders, data loggers or SCADA systems. The alarm outputs can alert plant operators to an out-of-range chlorine residual, or trigger an autodialer in remote or off-hour situations. The measuring cell design incorporates several features to ensure accurate readings, such as; high-grade gold and copper electrodes, fixed sample and buffer feed rates, and continuous cell mixing and cleaning. Solid-state analog electronics provide stable, drift-free, residual readings and output signal. Electronic isolation eliminates problems from “gound-loop” and ensures operator safety. The analyzer is designed to be relatively maintenance-free, other than adding vinegar when it runs out. The use of vinegar as a pH buffer is simple, effective, economical, and environmentally friendly. Converting the analyzer to read total chlorine, is as simple as adding Potassium Iodide to the vinegar buffer.
|
Standard Package Includes:
• Wall Mount
• 4-20mA Isolated Output, 600 ohms
• High and Low Alarms
• LED Digital Readout
• Display PPM or Mg/L
Alarm Settings
• Standard Calibration Range (see chart page 10)
• NEMA 4X Enclosure
Electronics Only
• Buffer Feed Rate #14 tubing – (4.5 days buffer supply use) Tubing installed, #13 Tubing – (12.5 days
buffer supply use) Buffer bottle wall bracket included.
• Sample Tubing 1/4” ID x 3/8” OD flexible PVC tubing. 3 feet long.
• Discharge Tubing 2 – 5/8” ID x 3/4” OD flexible PVC tubing Each piece 3 feet long.
• 220 VAC Power Standard
• Wall Mounting Feet
• One Instruction Book
• Total or Free Chlorine Residuals When measuring total chlorine recommend using option 9 or 10 on page 7 to Feed Potassium Iodide solution.