Product highlights
- Designed for Motor and Cable Testing, Specialist Applications and Electrical Testing Markets
- Insulation Testing to 2.50 Kv (New)
- 200 GΩ Measurement Range at ≥ 1.00kv
- Guard Terminal for Testing of Equipment With High Surface Leakage Issues
- Stabilized Insulation Test Voltage to -0% +2% ±2V
- Variable Insulation Test Voltage from 50V to 999 V in 1V Steps
- Variable Insulation Test Voltage from 1.00 Kv to 2.50kv in 10V Steps
- Single Range, Fast Continuity Testing from 0.01Ω to 1MΩ
- 0.01mv to 600V TRMS AC and DC Voltage Measurement
- Test Result Storage and Bluetooth® Downloading
- Live Circuit Detection and Protection
- CATIV 600V Applications & IP54 Environmental Protection
- Rechargeable Options for Mains and Car Charging
MIT2500 features and USPs |
||
|
||
Feature |
Issues |
Solution |
Guard connection |
Leakage over material or equipment surface can significantly compromise insulation measurement |
Remove the leakage path so the measurement returns actual insulation values |
|
Equipment cam be prematurely replaced or repaired when they only needed a good clean. |
Provide Guard terminal performance that does not compromise instrument performance |
|
||
Stabilised O/P voltage |
Overvoltage on low voltage applications causes damage |
Limit test voltages to test voltage +2% |
Guessed output voltage |
Selected voltage now much closer |
|
Variable voltage setting |
Test voltage adjustment now easily |
|
Lower Insulation test |
Insulation testing only |
No need to swap to continuity range |
|
Frequently <0.1MΩ is mistaken for a low (zero) resistance path |
Extended range shows resistance down to 1k Ωs |
|
Competitors extend |
Combats the extended low range |
|
Confusing ranges |
Single auto-range |
|
Time consuming range |
Fully auto ranging and current |
|
Confusion limit alarms |
Wider limit alarm options on |
|
High continuity use discharges batteries quickly |
Recharge adaptor |
|
Poor battery life |
Improved battery autonomy increases |
|
High battery costs |
Reduced battery costs |
|
Stupid number of cells |
Sixth cells removes the wasted 6th |
|
Poor buzzer response |
Fast contact detection and buzz. |
|
Test times unnecessarily long |
Fast circuit measurement and |
Beep Beep! |
Short circuits missed |
Quick circuit identification |
|
Gaps between continuity |
Extended range from 0.01 Ω to 1.0 MΩ |
|
Difficult to pair, download |
Simple Download paring, and |