<%@ Register TagPrefix="uc1" TagName="TopSubBanner" Src="CommonControls/TopSubBanner.ascx" %> <%@ Register TagPrefix="uc1" TagName="TopBanner" Src="CommonControls/TopBanner.ascx" %> <%@ Register TagPrefix="uc1" TagName="Instruction" Src="CommonControls/Instruction.ascx" %> <%@ Register TagPrefix="uc1" TagName="LeftColumnNav" Src="CommonControls/LeftColumnNav.ascx" %> <%@ Register TagPrefix="uc1" TagName="Footer" Src="CommonControls/Footer.ascx" %> <%@ Register TagPrefix="uc1" TagName="RightColumnNav" Src="CommonControls/RightColumnNav.ascx" %> <%@ Page Language="vb" AutoEventWireup="false" Codebehind="default.aspx.vb" Inherits="StoreFront.StoreFront.DefaultPage" EnableViewState=True TargetSchema="http://schemas.microsoft.com/intellisense/nav4-0"%>
<% '@BEGINVERSIONINFO '@APPVERSION: 6.0.1.0 '@STARTCOPYRIGHT 'The contents of this file are protected under the United States 'copyright laws and is confidential and proprietary to 'LaGarde, Incorporated. Its use or disclosure in whole or in part without the 'expressed written permission of LaGarde, Incorporated is expressly prohibited. ' '(c) Copyright 2002 by LaGarde, Incorporated. All rights reserved. '@ENDCOPYRIGHT '@ENDVERSIONINFO %> <% Me.PageHeader %>
DCX-22 SELF CONTAINED WATER LEVEL DATALOGGERS |
Submersible absolute pressure transducer |
FEATURES:
|
Self Contained Water Level Dataloggers Product Description |
The DCX-22 Self Contained Water Level Dataloggers are highly accurate, self-contained, battery powered absolute pressure water level loggers designed to record water depth and temperature over long periods. The absolute pressure water level sensor, electronics and battery are housed in a rugged, double-sealed 316 stainless steel tube for long term submersible deployment. The DCX-22 Self Contained Water Level Dataloggers require no external wires and may be suspended with any suitable and secure cable. When it’s time to download the recorded data, the DCX-22 Self Contained Water Level Dataloggers are simply retrieved from the measurement point and the double sealed end cap is then removed to access the absolute pressure water level sensor’s data port.
DCX-22 Baro Barometric Pressure Logger
|
Self Contained Water Level Dataloggers Specifications |
DCX-22 Self Contained Water Level Dataloggers Power: Lithium-Battery 3.6 V Battery Life: 10 years @ 1 measurement/hour Communications: RS 485 digital Logger to PC: USB (optional RS232) Performance Linearity: 0.05 % FS Level Accuracy: 0.1% FS (max. 0.2% FS) Baro Accuracy: 1 mbar Long Term Stability: 0.5 mbar Overload: 2 x nominal range Temp. Compensation: 14 to 104 °F (-10 to 40 °C) (other ranges on request) Temp. Measurement Accuracy: 1.8°F (1°C) Recording Interval: 1 second to 18 hours Shortest Measuring Cycle: 1x per second Memory: 16,000 or 28,000 data points (depending on storing method) Body Material: Stainless Steel 316L (DIN 1.4435) O-ring: Viton® Dimensions: 7/8 inch (2.2cm) Diameter x 11 inch (28cm) Long Weight: 0.78 lb (355 g) Software Compatibility: WindowsTM 2000/NT/XP/ME and 9X |
Absolute Pressure Water Level Loggers Software Information |
The Self Contained Water Level Dataloggers software is compatible with Windows™ 2000/NT/XP/ME and 9X. Simple and well structured software with many functions, such as:
With this software the DCX-22 Self Contained Water Level Dataloggers can be configured and read out. The absolute pressure water level sensor’s data can be processed i.e. graphical representation, exportation, compensation of ambient pressure as well as conversion into water level. The online function shows actual measurements of the Self Contained Water Level Datalogger. Due to the modular structure of the software, customer-specific data formats can be implemented on request. On request, a handheld WindowsCE application for the absolute pressure water level sensor’s data read-out is available. |
Absolute Pressure Water Level Recorders Applications |
Self-contained Water Level Dataloggers work well for many users because the depth of deployment is not dependant on the length of the cable. For example, a 15 ft water level datalogger with vented cable might come with 25 or 30 feet of cable, which is the best solution if you know exactly where the water level datalogger is going to be installed and only foresee using it in applications with similar or shorter cable requirements in the future. But if you need to drop the water level datalogger over the side of a bridge, or off a high dock, or down a deep well hole where the static water level is many feet below surface, the water level datalogger’s 15′ sensor range is great but you might have to have 200 feet of cable to get to the water level measurement point. The self-contained Water Level Datalogger really shines in these situations, even though it requires a greater investment and requires a barometric compensating datalogger for full accuracy.
Other applications include – Monitoring Sites With High Vandalism Opportunity, Groundwater Monitoring, Stream and River Gauging, Irrigation Canals, inflow and infiltration studies, Wetland/Estuary Monitoring, Weirs and Flumes, and MUCH MORE… |
Self Contained Water Level Dataloggers Options |
DCX-22-2 Self Contained Water Level Datalogger 0-32.8 Feet (0 to 10 m) (PN# AVL002) |
DCX-22-3 Self Contained Water Level Datalogger 0-65.6 Feet (0 to 20 m) (PN# AVL003) |
DCX-22 Baro Barometric Pressure Logger (PN# AVL001) |
K-104A Self Contained Water Level Datalogger USB Communication Cable (PN# AVU100) |
K-103A Self Contained Water Level Datalogger RS232 Communication Cable (PN# AVS100) |
Be the first to review “Self Contained Water Level Datalogger”