TX100/200 ADJUSTABLE TURBINE FLOW METERS
Adjustable depth insertion turbine flow meters
FEATURES:
|
Adjustable Turbine Flow Meters Product Description
The TX100/200 series, adjustable insertion turbine flow meters, use ruby bearings and a non-drag pick-off to achieve a wide flow range and long life. A sensor mounted in the body of the turbine flow meter detects the passage of miniature magnets in the rotor blades. (Magnets are in 2 or 4 blades only.) The resulting square-wave signal can be sent from the turbine flow meters for hundreds of feet without a transmitter, over unshielded cable. This square wave signal can be sent directly to a PLC or other control, or can be converted using a blind 4-20mA output or flow rate and totalizer display.
Designed for modularity and versatility, the TX100/200 series, adjustable insertion turbine flow meters, have a current-sinking pulse output, which can be combined with the appropriate transmitter or indicator depending on the application. For rate and total display the FT415 or FT420 flow indicator can be mounted directly on the TX100/200 series adjustable insertion turbine flow meters or on a convenient wall. For a 4-20mA analog output only, the AO55 blind 4-20mA converter can be mounted directly onto the turbine flow meter or onto a nearby wall. If the TX100/200 series, adjustable insertion turbine flow meters, are being used with a programmable controller, the output signal can be fed direct with no other conditioning required.
The installation fitting of the TX100/200 series adjustable turbine flow meter is standard 1-1/2" male NPT, and can be directly threaded into ordinary saddles or threaded weld fittings. A depth adjustment system integrated into the design of the turbine flow meters allow two basic meter sizes to cover pipe sizes from 3" to 48".
Adjustable Turbine Flow Meters Specifications
Accuracy: +1% of full scale
Flow Range: 0.2 – 30 ft/sec (.06 – 9.14 m/sec)
Sensor/Output: Hall Effect Sensor – 12 VDC current sinking pulse
Maximum Pipe Pressure: 200 psi (14 bar)
Maximum Temperature: 200º F (93º C)
Pipe Size:
TX101: 3" – 10" (50-250mm)
TX201: 10" – 48" (250-1200mm)
Fitting Size: 1-1/2" NPT
Insertion Force: 0.44 x pressure in pipe
Power: 5 – 24 VDC, 1.5 mA
Materials:
Sensor Body: Brass, 316 SS
Rotor: Polypro
Shaft: Nickel-bound tungsten carbide
Bearings: Ruby
Cable: #22 AWG 3-con 18′ (6m)
Maximum Cable Run: 2,000′ (650m)
Weight:
TX101: 3 lbs (1.36 kg)
TX201: 3.4 lbs (1.54 kg)
Dimensions:
TX101: 4" square x 12" long (10cm square x 30.5cm long)
TX201: 4" square x 17" long (10cm square x 43.2cm long)
TX115: 15-3/4" (40 cm) tall w/ 2" male NPT
TX215: 21-3/4" (55 cm) tall w/ 2" male NPT
Adjustable Turbine Flow Meters Option
TX101B Adjustable Turbine Flow Meters (PN# BN0500) Brass adjustable turbine flow meters, for 3" to 10" pipe diameter. |
|
TX101S Adjustable Turbine Flow Meters (PN# BN0550) Stainless steel adjustable turbine flow meters, for 3" to 10" pipe diameter. |
|
TX201B Adjustable Turbine Flow Meters (PN# BN0600) Brass adjustable turbine flow meters, for 10" to 48" pipe diameter. |
|
TX201S Adjustable Turbine Flow Meters (PN# BN0650) Stainless steel adjustable turbine flow meters, for 10" to 48" pipe diameter. |
|
TX115B Hot Tap Adjustable Turbine Flow Meters (PN# BN0700) Hot tap brass adjustable turbine flow meters, for 3" to 10" pipe diameter. NOTE: Brass Unit/Bronze Ball Valve. |
|
TX115S Hot Tap Adjustable Turbine Flow Meters (PN# BN0750) Hot tap stainless steel adjustable turbine flow meters, for 3" to 10" pipe diameter. NOTE: 316 SS Unit/Bronze Ball Valve. |
|
TX215B Hot Tap Adjustable Turbine Flow Meters (PN# BN0800) Hot tap brass adjustable turbine flow meters, for 10" to 48" pipe diameter. NOTE: Brass Unit/Bronze Ball Valve. |
|
TX215S Adjustable Turbine Flow Meters (PN# BN0850) Hot tap stainless steel adjustable turbine flow meters, for 10" to 48" pipe diameter. NOTE: 316 SS Unit/Bronze Ball Valve. |
|
Optional Output Displays/Converters Meter mounted displays/converters include 18 feet of cable. |
|
FT415M/FT415W Battery Powered Pulse Output and Display (PN# BN0400/BN0410) Includes 3V replaceable Lithium. Specify meter (PN# BN0400) or wall (PN# BN0410) mounted. |
|
FT420M/FT420W Pulse & 4-20mA Output Display (PN# BM0200/BM0210) Requires 12-24VDC power. Specify meter (PN# BM0200) or wall (PN# BM0210) mounted. |
|
AO55M/AO55W Blind 4-20ma Converter (PN# BM0250/BM0260) Requires 24-36VDC power. Specify meter (PN# BM0250) or wall (PN# BM0260) mounted. |
Be the first to review “TX215B Hot Tap Brass Adj Turbine,12″-40″”