Model Name Description AT-5005 - Locates underground energized and de-energized wires, cables and pipes, eliminates exploratory digging in parking lots or under floors for buried pipes and wires
- New technology makes tracing much faster, accurate and unambiguous when compared to standard locators
- Three testing modes for best accuracy.
- Includes receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case and A-Frame
- Locates underground energized and de-energized wires, cables and pipes, eliminates exploratory digging in parking lots or under floors for buried pipes and wires
- New technology makes tracing much faster, accurate and unambiguous when compared to standard locators:
- Signal select and distortion alert icon indicates clean signal of the traced line, versus Òghost and ÔreturnÕ path signals coming from the neighboring lines
- Forward-looking guidance coil alerts for bends and ÒT
- Distance sensitive left/right guidance guides the user to the exact location of the buried utilities and eliminates Òblind searches for the line
- Three testing modes for best accuracy:
- Passive power mode (50, 60, 100 and 120 Hz) Ð tracing energized lines conducting current
- Passive radio mode (RF) Ð using surrounding radio waves to traceunderground object
- Active mode – T-5000 signal generator with broad frequency selection between 491 Hz and 166 kHz with induction mode or directly connected to the cable with test leads or optional clamp
- Active mode depth measurement up to 20Õ (6m)
- Bright color ? VGA receiver graphical display and audible signal indicators provide clear reading to the user
- Strong testing signal generated by 10 watt variable output transmitter for dependable depth and distance locating
- Powerful digital signal processing in both receiver and transmitter provides outstanding performance in tracing when compared to analog devices
- Automatic or manual gain mode allows respectively quick and easy tracing of the line or precise pinpointing of the fault
- Receiver Bluetooth¨ wireless communication for downloading relevant images and archiving of meaningful digital information (previous survey results)
- Ground fault locating with A-Frame adapter for power and telecom cables (optional for AT-5000)
- Precise pinpointing of buried services and exceptionally fast sound and meter response
- Rugged durable construction, weatherproof and drop resistant to 3Õ
- Includes receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case and A-Frame
FEATURE | AT-5000 | AT-3500 |
Depth measurement | 20 ft | 16 ft |
Passive tracing frequencies | 50 Hz, 60 Hz, 100 Hz and 120 Hz | 50 Hz / 60 Hz |
Transmitter frequency | Selectable: 491 to 166 kHz | Single, non-adjustable |
Receiver active frequencies (Hz) | 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 512, 577, 640, 982, 8k, 8.44k, 9.82k, 35k, 65.5k, 82k, 83k (Worldwide) |
32.768 kHz |
Receiver passive frequencies (Hz) | 50, 60, 100, 120, RF (14k-21k) Extended and special frequency sets available |
Range 1: radio 15 kHz to 23 kHz Range 2: power network 50 Hz / 60 Hz; optionally 100 Hz (can be adjusted by Amprobe service personnel) |
Receiver depth display accuracy | 0-10 ft: +/- (5 %+2) under ideal field conditions 10-20 ft: +/- 10% under ideal field conditions |
Range 1: radio +/- 20 % Range 2: power network +/- 20 % Range 3: transmitter +/- 5 % (>5m (6-FT)), +/- 20 % (<5m (15-FT)) |
Receiver depth range | Maximum 20 ft (600 cm) | Maximum 16 ft (488 cm) |
Receiver antenna (distance sensitive left/right guidance) | ¥ | – |
Line ID (signal select, guidance compass, distortion alert) | ¥ | – |
Specifications | |
Depth measurement: | 20 ft |
Passive tracing frequencies: | 50, 60, 100 and 120 Hz |
Transmitter frequency: | Adjustable from 491 to 166 kHz |
A-Frame ground fault locating: | Optional |
R-5000 Active frequencies (Hz): | 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 512, 577, 640, 982, 8k, 8.44k, 9.82k, 35k, 65.5k, 82k, 83k |
R-5000 Passive frequencies (Hz): | 50, 60, 100, 120, RF (14k-21k) extended and special frequency sets available |
R-5000 Depth display accuracy: | 0-10ft: ±(5%+2) under ideal field conditions 10-20ft: ±10% under ideal field conditions |
R-5000 Depth range: | Maximum 20ft (600 cm) |
R-5000 Battery type: | Li-ion rechargeable 9 AA alkaline |
R-5000 Antenna: | Distance sensitive left/right guidance |
R-5000 Dimensions: | 8 ? W x 13 ? H x 29 L (21.0cm x 33.7 cm x 74.3cm) |
T-5000 Output frequencies (Hz): | 491, 982, 8.44k, 9.82k, 35k, 82k, 83k (North America) 491, 577, 640, 982, 8.192k, 8.44k, 9.82k, 35k, 82k, 83k Extended and special frequency sets available |
T-5000 Output power: | Variable to 10W |
T-5000 Simultaneous output: | Up to three active frequencies |
T-5000 Controls: | Frequency select, measurement units (mA, Volts, Ohms, Watts), output power, Signal Selectª, menu, 4-way navigation, select, SFL, On/Off |
T-5000 Display indicators: | Battery status, audio volume, output mode, frequency setting, frequency output, % output in SFL or induction mode, output graph, loop resistance graph |
T-5000 Display: | 1/8 VGA monochrome |
T-5000 Battery life: | NiMH rechargeable or six (6) D alkaline |
T-5000 Dimensions: | 11 W x 6 ? H x 9 L (27.9 cm x 17.1 cm x 22.9 cm) |
T-5000 Regulatory compliance: | FCC, CE |
T-5000 Environmental: | IP54 |
Included accessories: | Receiver (R-5000), transmitter (T-5000), connection cable, ground stake, ground cable, and carrying case |